jaeclimate.blogg.se

Siemens step 7 stuck on check before loading
Siemens step 7 stuck on check before loading








siemens step 7 stuck on check before loading

Before turning the status to Red/Green, make sure whether the load is of Full/Delta and also the time stamp is properly verified.After completion of the job force complete. Even after reprocessing the tRFC, if the job is in yellow status then turn the status into “Red”. If it is finished, then check whether any tRFC/IDOC struck/Failed with the help of SAP BASIS. Info Pack Long Run: If an info pack is running long, then check whether the job is finished at source system or not.If the data is loading from the source system to DSO directly, then delete the bad request in the PSA table, then restart the job.In such case reprocess the tRFC/IDOC with the help of SAP BASIS, and then job will finish successfully. In case of any failed tRFC’s/IDOC’s, the error message will be like “Error in writing the partition number DP2” or “Caller 01, 02 errors”.Go to RSA1 -> select source system -> System -> Connection check. Check the source system connection with the help of SAP BASIS, if it is not fine ask them to rebuild the connection.The following are the reasons for Info Pack failure. Go to PSA -> select request -> select error records -> edit the records and save. If it is not possible, then after getting the approval from the business, we can edit the Erroneous records in PSA and then we have to run the DTP. When ever a DTP fails because of erroneous records while fetching the data from PSA to Data Target, in such cases data needs to be changed in the ECC. After increasing the space in the F fact table we can restart the job. Table size needs to be increased before performing any action in BW. If the failure is due to “Space Issue” in the F fact table, engage the DBA team and also BASIS team and explain them the issue.Before restarting the Job/ repeating the DTP step, make sure about the reason for failure.If a DTP is taking log time than the regular run time without having the back ground job, then we have to turn the status of the DTP into Red and then delete the DTP bad request (If any), repeat the step or restart the job.After successful competition of the job uncheck the Handle Duplicate records option and activate.

Siemens step 7 stuck on check before loading update#

Go to the info provider -> DTP step -> Update tab -> check handle duplicate records -> activate -> Execute DTP. Before restarting the job after deleting the bad DTP request, we have to handle the duplicate records. In case of duplication in the records, we can find it in the error message along with the Info Provider’s name. Select the step-> right click and select “Display Message”-> there we will get the message which gives the reason for ABEND.Ī DTP can failure due to following reasons, in such case we can go for restarting the job.

siemens step 7 stuck on check before loading

Hope it will be helpful for the people who are working in support environment. Hi All…here is the list of SAP BI Production Support issues along with the resolution.










Siemens step 7 stuck on check before loading